Power Connection

The CM8100 models have dual power inlets with auto failover built in. These power supplies accept AC input voltage between 100 and 240 VAC with a frequency of 50 or 60 Hz. See the following tables for typical power draw.

Two IEC AC power sockets, which use conventional IEC AC power cord, are located on the power side of the metal case.

Dual DC Power Supply. DDC models have a dual DC power supply with screw-in DC terminals (supplied).

Note: Country specific IEC power cords are included with the CM8100.

See also Dual Power Supply and System Alerts - Power.

Console Manager platform (CM8100) Environmental and Power
Power Supply Dual AC
Power Draw
CM8100
Typical ly <15W 
Power Draw
CM8100-10G
CM8148-10G <25W Typical
CM8196-10G <30W Typical.
Operating conditions Temperature 5~50C, Rel Humidity 5~90% 
Cooling Passive 
Power Draw Sensors Active multi-zone power draw monitoring of 12V power. No monitoring on 120V AC.
Console Manager platform (CM8148-10G-5G and CM8196-10G-5G) Environmental and Power
Dual AC Dual socket universal IEC C13 inlet 100-240V AC 50/60Hz (x2)
Dual DC CM8148-10G-5G +/- 40V to 72V DC, 1.5A - 0.75A (x2)
CM8196-10G-5G +/- 40V to 72V DC, 2A-1A (x2)
Power Consumption CM8148-10G-5G Less than 25W (85 BTU/h) typical
CM8196-10G-5G Less than 30W (102 BTU/h) typical
Operating conditions 5°C to 50°C, 41°F to 122°F built-in temperature sensor, Humidity 5% to 90% (non-condensing),
Cooling Passive Cooling - can be forward or reverse mounted
Power Draw Sensors Active multi-zone power draw monitoring of 12V power. No monitoring on 120V AC.