Device Status LEDs

The LED states shown in the following table are determined through user-configurable threshold values for the Cell LED Amber / Green light, and modem enabled / disabled information.

  Status LEDs
  LED Condition
  LED Off Amber
Flashing
Amber Solid Green
Flashing
Green solid
Power

Device is off.   On a dual power supply system:
Only one PSU is connected.
  On a single power supply system:
The power is connected.

On a dual power supply system:
Redundant power is connected.
Heartbeat

Device has halted. Device is booting.   Normal
operation.
Device is
halted.
Network

No active network connection Device is failover starting. Device is in failover. Normal network connection is stopping, or normal network is up and failover is stopping. Network is
connected.
  CM8100 ONLY
NET1 No active network connection Network activity Network link (any speed) N/A Network link 1G.
NET2 No active network connection Network activity Network link (any speed) N/A Network link 1G.
    CM8100-10G ONLY
NET1 No active network connection Network activity Network link Network activity 10G Network link 10G.
NET2 No active network connection Network activity Network link Network activity 10G Network link 10G.
NET3 No active network connection Network activity Network link (any speed) N/A Network link 1G.
NET4 No active network connection Network activity Network link (any speed) N/A Network link 1G.


IOIO

      Any serial activity is received, on either console/usb console or device serial ports.  
Note:
  • The amber LED signal threshold configuration is set to 50%.of normal signal strength.
  • OM1200 series devices do not have a cloud LED, therefore, no LED indication is available for LSP or Lighthouse.

For information on the setting of network and power alert thresholds, see: