SNMP Manager Settings
To enable SNMP Manager:
-
In the Settings Pane, select
> SERVICES > Alerting and Monitoring.
The ALERTING AND MONITORING page displays with the SNMP MANAGER tab selected. -
Select Enabled to enable the SNMP Manager.
-
Select one of the following to set the Manager Protocol: UDP, UDP over IPv6, TCP, or TCP over IPv6.
-
Enter the Manager Address to receive SNMP messages.
-
Enter the Manager Port: the TCP/UDP port number to send SNMP messages to.
-
Select one of the following for the the SNMP protocol Version: v1, v2c, or v3.
Additional fields display depending on the version selected. -
Complete the following actions depending on the selected SNMP protocol Version:
-
If you selected v1, enter the SNMP Community to use for messages.
-
If you selected v2c:
-
Set the SNMP Message Type to TRAP or INFORM.
-
Enter the SNMP Community to use for messages.
-
-
If you selected v3:
-
Set the SNMP Message Type to TRAP or INFORM.
-
Optional: If you select TRAP for the SNMP Message Type, specify an Engine ID for sending an SNMP TRAP message.
Note: If the Engine ID is left blank, the auto-generated Engine ID from the SNMP Service is used. An Engine ID is not required for an SNMP INFORM message.
-
Enter the SNMP v3 Engine ID and required Configure SNMP Manager Settings.
-
Enter the Username to send the messages as.
-
Set the Authentication Protocol to MD5 or SHA.
-
Enter the Authentication Password for the SNMP user.
-
Set the Privacy Protocol to DES or AES.
-
Enter a Privacy Password.
-
-
-
Under SNMP Message Settings, set the events to trigger a TRAP/INFORM notification by checking a combination of:
-
Node Connection Status: send an SNMP notification when a node connects or disconnects.
-
Secondary Replication Status: send an SNMP notification when problems occurs with database replication on secondary Lighthouse.
-
Node Cellular Health Status: to use Cellular Health Status change traps.
-
- Click Apply.
For information on the structure of notifications for Opengear nodes, refer to OG-LIGHTHOUSE-MIB.mib.